sound velocities between ۱۰۰۰ - ۹۰۰۰m/s (۰.۰۷۹-۰.۳۵ in/ms)-covers
virtually all common engineering materials
|
Materials |
۰.۱mm (±۰.۰۰۴") or
۰.۱% of thickness measurement, whichever is greatest, when calibrated in
accordance with Cygnus instruments calibration procedure
|
Accuracy |
Multiple-Echo-۰.۱ or ۰.۰۵ mm (۰.۰۰۵" or ۰.۰۰۲")/ Single-Echo and Echo-Echo modes-۰.۰۱ mm ۰.۰۰۰۴
|
Resolution |
Twin crystal probes
(۵mm (۰.۲")-۷.۵MHz (T۷A
۸mm(۰.۳")۵.۰MHz(T۵B)standard
۱۳mm (۱/۲")-۲.۰MHz (T۲C) for
attenuative materials such as cast
metals, plastics and composites
|
Single crystal probe
(۶mm (۱/۴") - ۵.۰ MHz (S۵A
۱۳mm (۱/۲") -۲.۲۵ MHz (S۲C) standard
(۳.۵MHz (S۳C)or ۵.۰ MHz (S۵C
(۱۹mm(۳/۴") -۲.۲۵ MHz (s۲D |
Probes |
twin crystal probe in
Echo-Echo
۳-۵۰mm
|
Twin crystal probe in
single-Echo
۰.۷-۲۵۰mm
|
Single crystal
۱-۲۵۰mm |
Measurement
range in steel
|
Twin Lemo ۰۰
|
Connector |
AA batteries
|
Power |
۱۰hours minimum
|
Battery Life
|
Dual channel pulser
|
Electronics
|
۲.۴quarter VGA LCD
|
Display |
۱۳۲mm x ۸۲mm x ۳۴mm ۵.۲۰" x ۳.۲۳" x ۱.۳۴
|
Size |
۳۰۰grams (۱۰.۵۸oz) inc. batteries
|
Weight |
۱۰º C to ۵۰º C ۱۴ºF to ۱۲۲ºF-
|
Operating Temp
|
Capacity for up to ۵۰۰۰ points including A-scan
|
Data logging
|
Cyglink allow remote logging and viewing of A-scan graphs survey
and report generation to PDF file. Graphic analysis of data and statistical
calculation Designed for Windows ۷ and Windows ۸
|
Computer software
|
IP۶۷
MIL SDT ۸۱۰G Method ۵۰۱.۶ high temp +۵۵º C
MIL SDT ۸۱۰G Method ۵۰۲.۶ Low temp -۲۰º C
MIL SDT ۸۱۰G Method ۵۰۷.۶ Low humidity ۹۵%
MIL SDT ۸۱۰G Method ۵۱۲.۶ immersion- ۱ metre for ۳۰ mins
|
Environmental rating
|
MIL SDT ۸۱۰G Method ۵۱۴.۷ vibration- ۱ hour each axis
MIL SDT ۸۱۰G Method ۵۱۶.۷ shock ۲۰g- ۱۱ms half sine shock pulse,۴۰g ۱۱ms in each axis
MIL SDT ۸۱۰G Method ۵۱۶.۷ ۲۶ drops- transit drop ۱.۲۲ m
Compliance:CE,British Standard BS EN ۱۵۳۱۷:۲۰۱۳
|
Shock and Impact
|
CE,British Standard BS EN ۱۵۳۱۷:۲۰۱۳
specification for the characterization and verification of
ultrasonic thickness measuring equipment
|
Compliance |
RoHS,WEEE compliant
|
Environmental |
۳years on gauge and ۶ month on probe
|
Warranty |
|
|
|
|